WARNING SHUT OFF AND
DEPRESSURIZE AIR SYSTEM
BEFORE SERVICING OR
INSTALLING. MAXIMUM
OPERATING PRESSURE 250 PSI
- Maximum
working temperature at 145
psi 50 deg C / 122 deg F
- Install
the system as close as
possible to point of use
- Always
install the system with the
arrows indicating the
direction of airflow.
- The
lubricator must be filled
before the system is
pressurized
- The oil
recommended for lubricator
is ISO and UNI FD 22 (e.g.
ENERGOL HLP 22 ""BP";
SPINESSO 22 "ESSO"; PHYDRUS
OIL 22 "IP"; MOBIL DTE 22
"MOBIL"; TELLUS OIL 22
"SHELL"
- Do not
use cleaning oil, or brake
fluid oil, or solvents
The Modular Tsunami
Separator and lubricator may
be installed on airdrops or
mounted on machines.
Mounting brackets and
anchors have been included
for wall mounting if needed.
(Use a ¼" masonry drill for
plastic anchor.
Connect the air inlet to
port. This is a ½" NPT
female pipe, 3/8" and ¼"
bushings can be used to
reduce pipe size if needed.
The outlet port is ½"
NPT female pipe, 3/8" and ¼"
bushings can be used to
reduce pipe size if needed.
The system works best when
point of use air is within
30 feet from unit.
Set the drip rate on the
lubricator for approximately
two drops per 35 SCFM of air
flow. Use a flat blade screw
driver to adjust .
Use a 3/8" ID air hose
for best results for air
tools
The Tsunami Separator
comes with a automatic drain
PN 9000801. As water
accumulates in bottom sump
the drain will automatically
eject this water at a
predetermined level.
Unit can be mounted using
the optional mounting
bracket & hardware, P/N
21999-0144.
When using the enclosed
plastic drain line tubing,
heat the end of the tube
slightly before pushing it
into the drain stem.
MAINTENANCE:
If the automatic drain
should become stuck open or
inoperable Shut off air and
bleed all pressure from
separator before servicing.
Remove the bottom cap on the
separator. The drain usually
can be cleaned in hot soap
and water. DO NOT attempt to
disassemble the drain as you
may cause it to become
inoperative permanently.
When installing a new
drain, make sure o-ring is
installed on bottom stem (D)
before screwing into bottom
cap. Snug finger tight.
View Float Drain Replacement
Instructions
The Tsunami Separator
uses a special 304 stainless
steel filter element and
should never need replacing.
The filter element may be
removed and cleaned with
soap & water and
reinstalled.
FILLING & SETTING THE
LUBRICATOR
Remove and fill the oil
reservoir with approved oil.
Re-attach to head.
Set the amount of oil to
be introduced into the
airstream by adjusting the
orifice control using a
screwdriver. |